Tracers / [18F]BPAM121

[18F]BPAM121

Also written as [18F]BPAM121; [F-18]BPAM121; BPAM121
Radionuclide
F-18 t½ 109.7 min
Modality
PET
Production route
Cyclotron liquid target
Stage
Research
Syntheses indexed
1

What it is

Compound class
Target / mechanism
AMPA receptor (ionotropic glutamate receptor) positive allosteric modulator PMID 30740927 / DOI 10.1002/cmdc.201800816
Clinical application
(preclinical only) proposed PET radiotracer for imaging AMPA receptors in Alzheimer's disease; evaluated in mice PMID 30740927 / DOI 10.1002/cmdc.201800816
Theranostic pair

Regulatory status

FDA
No Drugs@FDA / openFDA drug registry — no approved application found; search: https://www.accessdata.fda.gov/scripts/cder/daf/index.cfm?event=BasicSearch.process&searchTerm=BPAM121
EMA (centralised)
Other approvals
Brand names

Clinical use

Typical injected activity
Uptake time

Reported in the literature. Not a dosing recommendation.

Published syntheses

ModuleCassettePurificationYield %RCP %Precursor / supplierSource
tosylated precursor30740927
2019 ChemMedChem
using a commercial FASTlab synthesizer from GE Healthcare

Precursor

Common precursor
Tosylated precursor (nucleophilic [18F]fluorination); synthetic procedure reported in the source PMID 30740927 / DOI 10.1002/cmdc.201800816
Suppliers seen in the literature
Typical final purification
HPLC

Need this precursor?We can point you to suppliers for [18F]BPAM121, or handle the enquiry for you.

Get in touch

Quality control Preliminary — inferred from compound class

Ph. Eur. monograph
USP monograph
AppearancepHRCP HPLCRCP TLCHPLC UVRadionuclidic (HPGe)Half-lifeActivityEndotoxins (LAL)SterilityFilter integrity
How this set was arrived at. base set per Ph. Eur. general monograph 0125 (rule); organic-phase radiosynthesis assumed from isotope/compound class, no synthesis data confirming it -> GC residual solvents (preliminary); conventional nucleophilic 18F-fluorination assumed from isotope/compound class, no synthesis data confirming K222 use -> Kryptofix test (preliminary)

Tests listed by reference only. Monograph texts are copyrighted and are not reproduced here. How these are derived

Setting up quality control?We can help you scope the equipment needed to release [18F]BPAM121.

Get in touch

Notes

Target and application not filled - to be taken from the publication.