[11C]L-glutamine
Also written as [11C]L-Glutamine; [C-11]L-Glutamine
- Radionuclide
- C-11 t½ 20.36 min
- Modality
- PET
- Production route
- —
- Stage
- —
- Syntheses indexed
- 2
What it is
- Compound class
- Radiolabelled natural amino acid (L-glutamine analogue)
- Target / mechanism
- Glutamine utilization/transport as carbon source for cancer cell metabolism (glutaminolysis) PMID 30359787
- Clinical application
- PET imaging of glutamine metabolism (glutaminolysis) in cancer, including triple negative breast cancer (TNBC) PMID 31659517
- Theranostic pair
- —
Regulatory status
- FDA
- —
- EMA (centralised)
- —
- Other approvals
- —
- Brand names
- —
Clinical use
- Typical injected activity
- —
- Uptake time
- —
Reported in the literature. Not a dosing recommendation.
Published syntheses
| Module | Cassette | Purification | Yield % | RCP % | Precursor / supplier | Source |
|---|---|---|---|---|---|---|
| Synthra HCNplus Synthra | custom manifold | HPLC+SPE | 43-52% yes | >90% | (S)-tert-butyl-2-((tert-butoxycarbonyl)amino)-4-iodobutanoate ABX | 31659517 2019 EJNMMI Radiopharm Chem Synthra HCN Plus automated synthesis module — The decay corrected yield from the [11C] cyanide trapping into the reaction vessel was 43–52% (n = 4). |
| TRACERlab FX2 N GE HealthCare | custom manifold | HPLC+SPE | >70% decay corrected; 15% non-decay-corrected yes | >99% | (S)Tert-Butyl 2-((tert-butoxycarbonyl) amino)-4-Iodobutanoate Advanced Biochemical Compounds, ABX, Germany | 30359787 2018 Nucl Med Biol The preparation of [11C]Gln was carried out on the the GE FX2N platform. — the radiochemical yield was significantly improved to over 70% decay corrected and to 15% non-decay-corrected (based upon the [11C]HCN trapped) |
Need this precursor?We can point you to suppliers for [11C]L-glutamine, or handle the enquiry for you.
Get in touchQuality control Preliminary — inferred from compound class
- Ph. Eur. monograph
- —
- USP monograph
- —
How this set was arrived at. base set per Ph. Eur. general monograph 0125 (rule); weak UV chromophore (sugar/simple ion/short-chain acid) -> conductometric detection (rule); organic-phase radiosynthesis assumed from isotope/compound class, no synthesis data confirming it -> GC residual solvents (preliminary)
Tests listed by reference only. Monograph texts are copyrighted and are not reproduced here. How these are derived
Setting up quality control?We can help you scope the equipment needed to release [11C]L-glutamine.
Get in touchNotes
Added from reverse module search (stage 6); 2 article(s) with C-11.