Tracers / [68Ga]BCY18469
[68Ga]BCY18469
Also written as [Ga-68]Ga-BCY18469
- Radionuclide
- Ga-68 t½ 67.71 min
- Modality
- Therapy
- Production route
- —
- Stage
- Reported once
- Syntheses indexed
- 1
What it is
- Compound class
- EphA2-targeting bicyclic peptide (Bicycle®)
- Target / mechanism
- EphA2 (erythropoietin-producing hepatocellular receptor A2) PMID 39239524
- Clinical application
- —
- Theranostic pair
- —
Regulatory status
- FDA
- —
- EMA (centralised)
- —
- Other approvals
- —
- Brand names
- —
Clinical use
- Typical injected activity
- —
- Uptake time
- —
Reported in the literature. Not a dosing recommendation.
Published syntheses
| Module | Cassette | Purification | Yield % | RCP % | Precursor / supplier | Source |
|---|---|---|---|---|---|---|
| Manual synthesis | — | none | — | ≥98% | BCY18469 | 39239524 2024 Theranostics Radiolabeling with 68Ga was performed by mixing equal parts (40 - 150 µL) of 1.0 M HEPES buffer |
Need this precursor?We can point you to suppliers for [68Ga]BCY18469, or handle the enquiry for you.
Get in touchNotes
Added at stage 22: promoted from 'Reported once' (single-article, no diagnostic pair at discovery) because a full-text synthesis with extracted data exists in parsed-therapy.xlsx -- PMID(s): 39239524. Target/mechanism, clinical application, indications, approval and precursor fields still need per-agent research and are intentionally left empty.