Tracers / [68Ga]GaCl3

[68Ga]GaCl3

Also written as [68Ga]GaCl3; [Ga-68]GaCl3; gallium-68 chloride
Radionuclide
Ga-68 t½ 67.7 min
Modality
PET
Production route
Generator / Cyclotron liquid target / Cyclotron solid target
Stage
n/a
Syntheses indexed
5

What it is

Compound class
Radiometal starting material
Target / mechanism
n/a
Clinical application
68Ga chloride solution used to radiolabel 68Ga PET radiopharmaceuticals (not for direct use in patients) EMA EPAR GalliaPharm - https://www.ema.europa.eu/en/medicines/human/EPAR/galliapharm
Theranostic pair

Regulatory status

FDA
EMA (centralised)
Yes — 2024; GalliaPharm (also GalenVita); Eckert & Ziegler Radiopharma GmbH; EMEA/H/C/006053 EMA medicines register, EPAR GalliaPharm, marketing authorisation issued 2024-08-01 — https://www.ema.europa.eu/en/medicines/human/EPAR/galliapharm
Other approvals
Brand names
GalliaPharm; GalenVita (EU, EMA — 68Ge/68Ga generators)

Clinical use

Typical injected activity
Uptake time

Reported in the literature. Not a dosing recommendation.

Published syntheses

ModuleCassettePurificationYield %RCP %Precursor / supplierSource
74.810041824275
2026 EJNMMI Radiopharm Chem
SPE97.89 %[68Ga]GaCl338447298
2024 Nucl Med Biol
using the FASTLab 2 synthesis module to produce [68Ga]GaCl3 equivalent to a 1.85 GBq generator
SPE66 ± 5%68Zn34763197
2022 Nucl Med Biol
using a single FASTlab time-list — average radiochemical yields of 66 ± 5%
68Zn-based solid target32056692
2020 Appl Radiat Isot
SPEZnCl231421441
2019 Nucl Med Biol
purified using octanol resin on an automated system

Precursor

Common precursor
68Ge/68Ga radionuclide generator eluate; or cyclotron production via 68Zn(p,n)68Ga on a liquid target EMA EPAR GalliaPharm - https://www.ema.europa.eu/en/medicines/human/EPAR/galliapharm; PMID 38006491 / DOI 10.1007/978-1-0716-3499-8_5
Suppliers seen in the literature
Typical final purification
SPE / cation exchange

Need this precursor?We can point you to suppliers for [68Ga]GaCl3, or handle the enquiry for you.

Get in touch

Quality control Pharmacopoeial monograph

Ph. Eur. monograph
2464 (generator-produced); 3109 (accelerator-produced)
USP monograph
not verified — the USP-NF monograph index is subscription-only and no public confirmation was found
AppearancepHRadionuclidic (HPGe)Half-lifeActivityMetal impurities
How this set was arrived at. Starting-material monograph. NB: Ge-68 breakthrough applies to the GENERATOR product (2464); the ACCELERATOR product (3109) instead requires control of Ga-66/Ga-67/Zn-65 and other accelerator-specific radionuclidic impurities. Sterility/endotoxin/appearance still apply.

Tests listed by reference only. Monograph texts are copyrighted and are not reproduced here. How these are derived

Setting up quality control?We can help you scope the equipment needed to release [68Ga]GaCl3.

Get in touch

Notes

Not a tracer. Listed because cyclotron-produced Ga-68 is a growing production route.