Tracer library / [18F]GE-180

[18F]GE-180
Also written as [18F]GE-180; [18F]GE180; [F-18]GE-180; [F-18]GE180; F-18 GE-180; F-18 GE180; F-18-GE180
- Radionuclide
- F-18 t½ 109.7 min
- Modality
- PET
- Production route
- Cyclotron liquid target
- Stage
- Clinical research
- Syntheses indexed
- 2
What it is
Regulatory status
- FDA
- No Drugs@FDA / openFDA drug registry — no approved application found; search: https://www.accessdata.fda.gov/scripts/cder/daf/index.cfm?event=BasicSearch.process&searchTerm=flutriciclamide
- EMA (centralised)
- —
- Other approvals
- —
- Brand names
- —
Clinical use
- Typical injected activity
- —
- Uptake time
- Static imaging window ~60-90 min post-injection used in practice; first-in-human study used a 210-min dynamic scan for kinetic modelling PMID 36906584 / DOI 10.1186/s12974-023-02749-2; PMID 27261523 / DOI 10.2967/jnumed.115.169078
Reported in the literature. Not a dosing recommendation.
Published syntheses
| Module | Cassette | Purification | Yield % | RCP % | Precursor / supplier | Source |
|---|---|---|---|---|---|---|
| AllinOne (AiO) Trasis | — | SPE | 69 ± 1.8% not corrected | — | — | 35349890 2022 Appl Radiat Isot The nucleophilic radiofluorination was performed on an AllinOne synthesis module by SPE purification method - non-decay corrected radiochemical yields of 69 ± 1.8% in 32 min |
| FASTlab GE HealthCare | — | SPE | 48% not corrected | ≥95% | S-enantiomer mesylate precursor | 24448744 2014 J Labelled Comp Radiopharm An optimized, automated synthesis of [(18) F]GE-180 has been developed for the GE FASTlab™ synthesizer. - The average radiochemical yield is 48% (RSD 6%, non-decay corrected) |
Clinical literature
Clinical studies in the indexed corpus, ordered by design (multicentre, prospective, retrospective, others, case reports last) and then by year. Titles and links only, as published; this is not a summary of the evidence.
Precursor
- Common precursor
- S-enantiomer mesylate precursor (nucleophilic [18F]fluorination) PMID 24448744 / DOI 10.1002/jlcr.3112
- Suppliers seen in the literature
- —
- Typical final purification
- SPE
Need this precursor?We can point you to suppliers for [18F]GE-180, or handle the enquiry for you.
Get in touchQuality control Preliminary - inferred from compound class
- Ph. Eur. monograph
- not verified No Ph. Eur. check is recorded for this entry.
- USP monograph
- not verified No USP check is recorded for this entry.
How this set was arrived at. base set per Ph. Eur. general monograph 0125 (rule); organic-phase radiosynthesis assumed from isotope/compound class, no synthesis data confirming it -> GC residual solvents (preliminary); conventional nucleophilic 18F-fluorination assumed from isotope/compound class, no synthesis data confirming K222 use -> Kryptofix test (preliminary)
Tests listed by reference only. Monograph texts are copyrighted and are not reproduced here. How these are derived
Setting up quality control?We can help you scope the equipment needed to release [18F]GE-180.
Get in touch